GTO 4000XL Instruction Manual © 091610 13
IMPORTANT:
• Thetransformerisdesignedandintendedforindooruse.Ifthetransformercanbeplugged
only into an outside electrical outlet, a weatherproof cover/housing (available at local electrical
supply stores) must be used.
• TheonlywireacceptableforusewithGTOproductsis16gaugemulti-stranded,lowvoltage,
direct burial wire [RB509]. This particular gauge enables the transformer to provide an
adequate charge through the control board to the battery at distances up to 1000 ft.
• DONOTusetelephonewireorsolidcorewire;thesetypesofwiredonotdeliverenough
voltage for your gate operator to function and will cause the system to go into a condition
known as “low voltage lockout.
• NEVERsplicewirestogether.Splicingpermitscorrosionandseriouslydegradesthewires
ability to carry an adequate current.
• NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME! Doing so will
damage the control board.
• Ifyourgateismorethan1000ft.fromanACpowersource,youwillneedtouseatleast10
watts solar charging power [FM122/FM123] to charge the battery. Refer to the Solar Panels
and Gate Activity Chart on page 2.
Step 1
Make sure the control box power switch is OFF.
Step 2
Select the electrical outlet outlet into which you will plug the transformer. Measure the distance from this
outlet to the control box following the path where the wire will be laid (allow for an additional 6” to be
pulled into the control box). Measure the wire and cut to the appropriate length.
Step 3
Lay the measured length of low voltage wire in a trench
following a path from the selected electrical outlet to the
control box. Wires coming up from the ground should be
run through PVC conduit to protect them from lawn mower
blades, weed eaters, and grazing animals. Bury the wire in the
trench.
Step 4
Feed the low voltage wires upward through the strain relief
opening on the lower left of the control box. Pull 6” to 8” of
wire into the control box.
Connect the Transformer
ON/OFF Switch
Low Voltage Wire
from Transformer
Power Cable from
Master Arm
PVC Pipe
25
FUSE
BATT +
BATT -
1 2 3 4
ON DIP
STATUS
LEARN RMT
RECEIVER
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
ALM
S2
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
CHARGING
PWR IN
GTO RCVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
GTO
TRANSF
LOCK
PWR
AUX
RLY
POWER
INPUTS
CONTROL
OUTPUTS
MASTER CABLESLAVE CABLE
CONTROL INPUTS
AUTO CLOSE TIME STALL FORCE
CLOSE
EDGE
18 VAC
or
SOLAR
GTO
LOCK
AUX
Seitenansicht 22